Owner’s Manual
KGiimorG
Room Air Conditioner
Model Numbers 78079,70089,70129,78189
A CAUTION
Read and follow all safety rules and
operating instructions before using
this product.
Safety
Installation
Operation
Maintenance
Troubleshooting
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - KGiimorG

Owner’s ManualKGiimorGRoom Air ConditionerModel Numbers 78079,70089,70129,78189A CAUTIONRead and follow all safety rules and operating instructions be

Pagina 2 - Warranty

Installation4. See Figure 9. Place bubble level between indoor silt and outdoor end of support bracket. Turn adjusting foot on support until level ti

Pagina 3

Installation9. See Figure 13. Slide front grille to left; pull out to remove. Slide air filter to left; pull out to remove. Remove 4 screws securing

Pagina 4 - Model Identification

InstallationWindow Installation—12000, and 18000 Btu UnitsModels 70129,78189)___________________A CAUTIONTo avoid risk of personal injury, propert

Pagina 5 - Sizing Instructions

InstallationInstallation RequirementsSee Figure 17. Inspect window track, sash, and sill. Ensure window will bear weight of air conditioner for extend

Pagina 6

InstallatotiMobile Home Window ModificationSee Figure 19. Mobile home window modification requires adding wood strip at least 1wide along entire width

Pagina 7

InstallationFigure 22. Installing Outer Case in Window1. Indoor sash2. Top rail3. Window sill gasket4. Bottom rail4. See Figure 23. Secure case to

Pagina 8

InstallationA CAUTIONTo avoid damage to outside wall of house, especially if wall is weak or outside supports sit between studs in wall, place wood bl

Pagina 9

InstallationFigure 29. Installing Seal Strip1. Seal strip2. Outdoor sash3. Indoorsash12. See Figure 30. Under normal conditions, unit can evaporat

Pagina 10 - A CAUTION

InstallationGeneral InstructionsSee Figure 32. Dimensions of finished opening (required) in wali are:• 24%” wide by 16%" high (12000 Btu model).

Pagina 11 - Installation

InstallationFigure 34. Securing Outer Case in Wall Opening1. Lintel and flashing (if required)2. Provide W slope to outside for condensate drainage3

Pagina 12

ContentsWarranty... 2Safety Instructions...

Pagina 13

ControlsFigure 37. Touch Control Panel•• m. -m(off)SMARfSETLOWCOOLMEDCOOLHIGHCOOLpower),'^llÍDELAY)(sTARTj DBBBIBB.MODESETEXHAUST CLOSEDSee Figu

Pagina 14 - Installatoti

Operating InstructionsBefore Turning Air Conditioner OnTo operate air conditioner efficiently and ensure itprovides maximum comfort;• Tightly close a

Pagina 15

Operating InstructionsDelay Start Operation To program delay start:1. Turn unitoff (press OFF pad).2. Press DELAY START pad. Display flashes current

Pagina 16

Operating InstructionsNormal Operating SoundsCertain sounds may be made when air conditioner runs, especially in a cooling mode. Sounds may include:•

Pagina 17

Care and MaintenanceMaintenance ProceduresЛ WARNINGTo avoid death or personal injury due to electrical shock, turn off fan control and unplug power co

Pagina 18

Care and MaintenanceEvaporator Coil, Condenser Coil, and Base Pan Maintenance NOTE: See Figures 1 and 2 on page 4 for location of air conditioner comp

Pagina 19

TroubleshootingThe following table describes some common problems that may be encountered with a room air conditioner. Each problem is accompanied by

Pagina 20 - Controls

TroubleshootingProblemPossible Cause SolutionUnit does not adequately cool room or area.• Desired temperature set too high.• Excessive heat or moistur

Pagina 21 - EXHAUST

For in-home major brand repair service:Call 24 hours a day, 7 days a week1-800-4-MY-HOME“ (1 -800-469-4663)Para pedir servicio de reparación - 1-800-6

Pagina 22 - \/

Safety InstructionsRecognize Safety Symbols, Words, and LabelsThe following symbols and labels are used throughout this manual to indicate immediate o

Pagina 23 - A WARNING

Model IdentificationEvery Kenmore Room Air Conditioner has an identification plate showing model number, part number, serial number, and power require

Pagina 24 - Л WARNING

Sizing InstructionsMany complaints about room air conditioners result from units that are over-sized or under-sized for a given area. Over-sized units

Pagina 25

Installationinstalling Room Air ConditionersProper installation of a room air conditioner helps ensure trouble-free operation. Improper installation c

Pagina 26 - Troubleshooting

InstallationReceptacle WiringReceptacle wiring must be of adequate size for unit. Refer to unit identification plate for exact power requirements. Pow

Pagina 27 - %" to %" to

InstallationInstallation RequirementsSee Figure 4. Inspect window track, sash, and sill. Ensure window will bear weight of air conditioner for extende

Pagina 28 - HomeCentrar

Installation2. See Figure 8. Thread adjusting foot (Item B) through bottom of support bracket (Item C). Measure width of window and mark center point